B0100
| Property | Specification |
| Data System | MDS |
| Data Specs | V1.12.0 |
| Description | Comatose |
| Group | Asmt |
| Type | Code |
| Length | 1 |
| Fixed Start-End | 511-511 |
| Version Notes |
| Item Subsets | |
| Active | NC,NQ,NP,NSD,NO,NOD,ND,SP,SSD,SO,SOD,SD |
| Inactive | NS,NT,SS,ST,XX |
| State optional | |
| Item Values | ||
| Value | LOINC | Text |
| 0 | No | |
| 1 | Yes | |
| - | Not assessed/no information | |
| Item Edits | |||
| Edit ID | Type | Severity | Edit Text |
| -3676 | Format | Fatal |
Values of Code and Checklist Items: Only the coded values listed in the "Item Values" table of the Detailed Data Specifications Report may be submitted for this item. |
| -3825 | Consistency | Fatal |
a) If B0100=[0] and A0310G=[1,^], then if C0100 is active it must not equal [^]. b) If B0100=[-] and A0310G=[1,^], then if C0100 is active it must equal [-]. c) If B0100=[0] and A0310G=[2] and (A0310A=[01,02,03,04,05,06] or A0310B=[01,02,03,04,05,06,07]), then if C0100 is active it must not equal [^]. d) If B0100=[-] and A0310G=[2] and (A0310A=[01,02,03,04,05,06] or A0310B=[01,02,03,04,05,06,07]), then if C0100 is active it must equal [-]. |
| -3826 | Consistency | Fatal | If B0100=[0,-] and A0310G=[2] and A0310A=[99] and A0310B=[99], then all active items from C0100 through C0600 must equal [^] and all active items from C0700 through C1000 must not equal [^]. |
| -3835 | Consistency | Fatal |
a) If B0100=[0] and A0310G=[1,^], then if D0100 is active it must not equal [^]. b) If B0100=[-] and A0310G=[1,^], then if D0100 is active it must equal [-]. c) If B0100=[0] and A0310G=[2] and (A0310A=[01,02,03,04,05,06] or A0310B=[01,02,03,04,05,06,07]), then if D0100 is active it must not equal [^]. d) If B0100=[-] and A0310G=[2] and (A0310A=[01,02,03,04,05,06] or A0310B=[01,02,03,04,05,06,07]), then if D0100 is active it must equal [-]. |
| -3836 | Consistency | Fatal | If B0100=[0,-] and A0310G=[2] and A0310A=[99] and A0310B=[99], then all active items from D0100 through D0650 must equal [^]. |
| -3837 | Consistency | Fatal | If B0100=[0,-] and A0310G=[2] and A0310A=[99] and A0310B=[99], then all active items from J0200 through J0850 must equal [^]. |
| -3831 | Consistency | Fatal |
a) If B0100=[0] and A0310G=[1,^], then if J0200 is active it must not equal [^]. b) If B0100=[-] and A0310G=[1,^], then if J0200 is active it must equal [-]. c) If B0100=[0] and A0310G=[2] and (A0310A=[01,02,03,04,05,06] or A0310B=[01,02,03,04,05,06,07]), then if J0200 is active it must not equal [^]. d) If B0100=[-] and A0310G=[2] and (A0310A=[01,02,03,04,05,06] or A0310B=[01,02,03,04,05,06,07]), then if J0200 is active it must equal [-]. |
| -3609 | Skip pattern | Fatal | If B0100=[1], then all active items from B0200 through F0800Z must equal [^]. |
| -3829 | Skip pattern | Fatal |
a) If B0100=[0], then all active items from B0200 through B1200 must not equal [^]. b) If B0100=[-], then all active items from B0200 through B1200 must equal [-]. |
| -3830 | Skip pattern | Fatal |
a) If B0100=[0], then all active items from C1300A through C1600 must not equal [^]. b) If B0100=[-], then all active items from C1300A through C1600 must equal [-]. |
| -3523 | Skip pattern | Fatal |
a) If B0100=[0], then all active items from E0100A through E0300 must not equal [^]. b) If B0100=[-], then all active items from E0100A through E0300 must equal [-]. |
| -3524 | Skip pattern | Fatal |
a) If B0100=[0], then all active items from E0800 through E0900 must not equal [^]. b) If B0100=[-], then all active items from E0800 through E0900 must equal [-]. |
| -3525 | Skip pattern | Fatal |
a) If B0100=[0], then all active items from E1100 through F0300 must not equal [^]. b) If B0100=[-], then all active items from E1100 through F0300 must equal [-]. |
| -3610 | Skip pattern | Fatal | If B0100=[1], then all active items from J0200 through J0850 must equal [^]. |
NOTICE: These materials are in the public domain and cannot be copyrighted.
Generated: 09/18/2012 02:37:26 PM